Jinchat have searched over the world for products with the finest quality and latest technology to introduce into our own country. Most imported products are from Europe and possess the common features : High Efficiency, Environmental Friendly with Reasonable Prices.

CRAC (Computer Room Air Conditioning Unit)

Jinchat is the no.1 CRAC providers in the Greater China area with a market share of more than 30%. The factory was located in Padova, Italy and has over 35 years’ experience in the manufacturing of CRACs.

All products are Eurovent Certified. The product ranges from 6kW to 200kW for chilled water unit and 6kW to 99kW for air-cooled unit, all equipped with the latest energy saving features such as EC fan and scroll digital compressor.


http://www.hiross.com


UPS (Uninterruptible power supply)

Uninterruptible Power Supply (UPS) is the key to a reliable, 7x24 operation. Jinchat has installed UPS systems from the most basic single phase units to sophisticated multi-module parallel redundant 3 phase installations serving larger, complex and more power sensitive operations ranging from 1kVA to 800kVA.


http://www.sicon-emi.com/sicon-emi_com.htm



Central Chiller Plant

The chiller can be water-cooled or air-cooled. The compressor types typically are reciprocating, scroll, screw or centrifugal. Using chilled water to cool a building or process is efficient and flexible. A two-inch Schedule 40 pipe of chilled water can supply as much comfort cooling as 42" diameter round air duct. The use of chillers allows the design engineer to produce chilled water in a central building location or even on the roof and distribute the water economically and without the use of large duct shafts. Chilled water also provides accurate temperature control that is especially useful for variable air volume (VAV) applications.


http://www.climaveneta.com.cn


Diesel Generator Set

As manufacturer of the first ever certified local made generator used in nuclear plant, Cooltech Backup Generators have everything to meet your specific needs.  Power ratings range from 10kVA to 2200kVA.  Your backup generator system can be customized with larger fuel tanks for longer run times, bypass options on automatic transfer switches for easy maintenance, sound attenuation enclosures for environmentally sensitive areas, and even custom colors to match the landscaping.


http://www.cooltechsh.com/


Electrical System

The key to an effective Data Center electrical power system is the manner in which distribution is accomplished.  Conditioning can be in the form of isolation and K rated transformers (to address harmonic loads), surge suppression and other protection features. Conditioning integrated with end point distribution via special cabling is synonymous with the well organized, well managed and flexible facility.

Jinchat have utilized various methods to accomplish this objective, addressing the different operational and physical needs of its customers.  Be it a completely new site, an old site needing improvement, a relocation project or simply a WR(2) renewal, there is a solution with Jinchat.


Water Detection System

Moisture below the floor can damage wiring or equipment and cause costly downtime.  An under floor water detection system can give you an immediate warning. Whether it is thousands square feet data center or hundreds square feet of computer room, Jinchat have different water leakage detection strategies to meet your needs and budgets.



Raised Floor System

Raised floor system creates a flexible chamber for wire management and the distribution of heating and cooling services as well as providing a clean and organized environment.

Jinchat source Raised Floor System from all over the world to match your taste, your budget and your technical needs. We have Italian-made panels completed with glass, marbles, metal and precious stones finishes to local-made panels for general use.



Fire Protection System

Fire protection is an absolute necessity for your business’ survival.  In the unfortunate event of a fire, heat and smoke can quickly damage delicate electronic equipment.  There are lots of available solutions to address the issue. Apart from the generally known FM200, Jinchat have many other choices. Whether you belong to the budget-type, the “Green” pioneer, or the “Safety is the First” kind, talk to our engineers and you will have it.



Facilities Monitoring System

The sooner you know a problem exists, the sooner the problem can be resolved.  With systems that are expected to be up 100% of the time, down time must be kept to a minimum.  With a site monitoring system you can monitor any or all of the following:

  • Power
  • UPS
  • Generator
  • Temperature/Humidity
  • Fire/Smoke
  • MVAC
  • Leak detection
  • Intrusion

From a simple few-thousand-dollars monitoring system to an extensive full-coverage monitoring plus control system, call Jinchat for a solution.